  • speedy05

    Replied to the thread Problem with command on CentOS 7.
    Post
    I got it! I removed icinga2 from the host and installed it again. after using the agent script, it works.
  • Can you give me a hint, how I could do that with the director? I tried to get a similar code in apply Service section, but I don't suceeded.
    I also had the idea before, to use datafields for each host, but I had no idea how the use these inputs for the…
  • speedy05

    Replied to the thread Problem with command on CentOS 7.
    Post
    Can you extract its path from the master, and verify that it is synced to the client then?
    Can you specify how I do that? Maybe in German ;-)
  • speedy05

    Replied to the thread Problem with command on CentOS 7.
    Post
    Thanks!

    I have the plugin running on a second CentOS. There are no errors and I get a very long output for "icinga2 object list --type CheckCommand --name check_linux_memory". However, on the server the response to the command is empty.
    So the command…
  • I tend to write such thresholds into the host. Like in this examples:

    (Code, 13 lines)


    Then I can access them via an apply rule like this:
    (Code, 13 lines)

  • Hello everyone,

    what is the best way to do this?

    I would like to define different thresholds for different services. For example, with the "Procs"service. Our virtual machines come with default settings of 250 for Warning and 400 for Critical. For…
  • speedy05

    Thread
    Hi everybody,

    I have a strange problem with Icinga 2, Icinga Web 2 and the Director. On all CentOS-servers I have installed the Nagios plugins (yum install nagios-plugins-all). Nevertheless, the commands for yum and check_linux_memory were missing on…
  • Hallo zusammen,


    wie realisiere ich folgendes am besten?


    Ich würde gerne bei verschiedenen Services verschiedene Schwellenwerte definieren. Z.B. beim "Procs"-Service. Bei unseren virtuellen Maschinen reichen die Standardeinstellungen von 250 für…
  • speedy05

    Post
    Yes, the notifications will be triggered nearly every minute. You can see here:
    (Code, 7 lines)


    (Quote)

    Yes! It was true! I changed it to false and now it works as I expected. I think I didn't understand the meaning of volatile until now.
    Thanks for…
  • speedy05

    Post
    Can anybody help?
  • speedy05

    Post
    I type 0, but the director renders it to 0s:
    Even if I enter 150m, the notifications will be sent every minute.


    Edit: both types are sent. I got messages, if a host is down and when a service (e.g. apt) has critical state.
  • speedy05

    Thread
    Hi,
    i have a problem with notifications, configured by director.

    I have these configurations:

    zones.d/icinga2.xxx.local/notification_apply.conf


    (Code, 10 lines)


    zones.d/icinga2.xxx.local/notification_apply.conf

    (Code, 9 lines)


    No matter which time…